How the HDTrace reports deviations - change detector, not a diagnosis

Copy from the HDTrace repository (docs/). Internal network details have been replaced by placeholders; the version in the repository is authoritative.

Findings — what the system reports, and what it does not claim

The rest of the program produces numbers. This part produces the one sentence somebody at the machine actually needs: what has changed, in which phase, at which sensor, what it might be, and how to check it.

The limits come first, not in the small print

This is not a diagnosis. It is a change detector against a taught state, plus a list of things whose frequency happens to lie where something has changed.

The difference is practical, not legal. A system that says “bearing damage” and is wrong twice gets switched off. A system that says “something has changed here, it could be X, Y or Z, and this is how you find out which in five minutes” stays useful even when the first guess was wrong.

What it can do

  • Change per phase against the taught good state, per sensor
  • Assign a line to a shaft, a bearing or the structure, with a named cause
  • Rolling bearing damage at stage 2–3 — weeks to months of lead time, enough to plan a spindle replacement
  • Unbalance, misalignment, chatter, a blunt wheel as a change in bands that were named beforehand
  • A hint when a sensor is no longer measuring cleanly

What it cannot do

  • Bearing damage at stage 1 (ultrasound above 20 kHz) — that needs a different sensor, not more software
  • Absolute vibration severity to ISO 20816 — piezo discs have no calibrated sensitivity
  • A measurement fit for acceptance testing
  • Diagnosis without people

What is measured

Frequency bands per phase and sensor, as defined in the configuration. Each band also carries its causes text there — what a rise in it usually means. That is in the configuration and is not derived, because the program cannot know it: the resonance band 1250–1550 Hz contains not a single passing frequency, yet it is exactly the range in which bearing impacts excite the structure. Only a human can say that.

Time domain characteristics per phase and sensor, to VDI 3832:

Characteristicrises with
RMS valuemore energy overall — process, wheel, coupling
Peak valueindividual hard impacts — knock, loose part
Crest factorimpulsive while the level is still low — early indicator of bearing damage
Kurtosissignal shape becomes peaky instead of noise-like — impact excitation

Crest and kurtosis matter particularly here because at 6 kSPS the ultrasound range, where a bearing announces itself first, is out of reach. The shape of the time signal changes before the spectrum does, though: a few hard impacts raise the crest factor while the RMS value is still almost unchanged.

One trap you have to know: if the crest factor falls again, that is not recovery. As the damage progresses the impacts become denser, the RMS value rises and the crest factor drops back towards its starting value. Only the pair of the two says which way things are going.

How the limit comes about

Not guessed, but measured. During teaching, the mean and the spread across the taught parts are recorded per band and characteristic:

Limit = max( mean × factor ,  mean + k × spread )

The statistical part is the textbook form. The factor in front of it is the protection against it: with four taught parts the spread is a poor estimate, and a phase that happened to run particularly evenly during teaching would otherwise get a limit a few per cent above its mean and would scream forever. The wider of the two wins — so the spread can only loosen a limit, never pull it below what is bearable.

Defaults: warn_factor 2,0 · alarm_factor 3,0 · k_sigma 3,0 · 4 taught parts.

Three rules against the flood of alarms

The documented way for such systems to die is alarm fatigue: if 99 out of 100 messages resolve themselves, the 100th is ignored as well. Three mechanisms stand against that.

Confirmation. A deviation is only reported when the same phase shows it several times in a row (findings.confirmations, default 2). A single noisy segment is not an event.

Hysteresis. A value oscillating around the limit would otherwise switch endlessly between reported and cleared. It has to fall clearly below it and do so several times (clear_factor, clear_after).

Non-stationary segments are skipped. A phase in which the machine was still accelerating is not comparable with a taught stationary one. Recognisable from the speed spread within the segment.

Plus two summary rules, without which one fault turns into twenty messages:

  • One finding per cause, not per phase. Grouping is by what has changed; the phase list hangs off it. That list is itself the most useful information — a fault that appears in the quiet phases and disappears under load reads completely differently from one that is only there while grinding.
  • The overall band is dropped when a narrower band inside it has triggered, and RMS/peak value are dropped when a band has triggered — both are then the consequence, not a second finding.

Measured on the simulator: unfiltered, one bearing fault produced 21 messages; with these rules, one.

Example

Bearing damage set to 0,8, reference from 4 parts:

ALARM — band “resonance band” in 6 phases, strongest in “approach” at 12,0× the taught value, strongest at the sensor grinding spindle front Phases: approach 12,1× · workpiece change 11,9× · retract 11,8× · cylindrical grinding 11,2× · circumference finishing 7,2× · roughing 4,1× Sensors: grinding spindle front 12,0× · grinding spindle rear 11,5× · workpiece spindle 3,8× · tailstock 1,8× Typical cause: impact excitation — rolling bearing damage excites this resonance → Change the shaft speed by ±10 %: if the line moves proportionally with it, it belongs to that shaft. If it stays put, it is the structure or the mains.

Two things are in the phase list that a single number would not give: the ranking of the sensors points to the grinding spindle and not to the tailstock, and in roughing the damage is almost invisible, because the grinding noise covers it. Anyone looking for it should look in the retract phase.

For comparison, with unbalance instead of bearing damage: three findings — order 1 at 35×, order 2 at 37×, order 3 at 18×, each with “unbalance of the grinding wheel” or “misalignment” and the matching frequency (grinding spindle rotational frequency 30 Hz). Two completely different fault patterns, two completely different messages.

Sensor notices

Because the system is meant to be installed by whoever operates the machine, the most likely fault is not a subtle misconfiguration but a bond that has come loose or a cable pulled out during set-up. A dead channel reports low values and therefore looks healthy.

Per segment and channel it is therefore checked whether a noise floor arrives at all (no signal), whether the signal is sitting at the converter end stop (overdriven), whether it moves at all (constant). Conspicuous channels appear at the top with the findings, not in a diagnostics menu.

Raw data with the finding

As soon as a finding is confirmed, the raw data window around the event is written to a file — pre-trigger from a running ring buffer, post-trigger afterwards, together with the finding text, the phase and the control values. That makes it possible to recompute an event later with different parameters instead of reconstructing it from memory. See aufzeichnung.md.